FAZ Miniature Circuit Breakers

  • Designed for resistive or slightly inductive loads
  • Response time of instantaneous trip: 3 - 5 x In current rating
  • UL recognized and CSA certified as Supplementary Protectors
  • For International and Domestic (U.S.A.) use (conform to IEC / EN60898)





  • Trip Curve "B" Breakers

    Suitable for applications where protection against low-level
    short circuit faults in control wiring is desired. Instantaneous trip
    is 3 to 5 x continuous rating of device (In). Applications include
    PLC wiring, business equipment, lighting, appliances and
    some motors. Low magnetic trip point.


    Rated
    Current
    In
    (A)
    1 pole2 poles3 poles4 poles
    TypeTypeTypeType
    6FAZ-B6/1FAZ-B6/2FAZ-B6/3FAZ-B6/4
    8FAZ-B8/1FAZ-B8/2FAZ-B8/3FAZ-B8/4
    10FAZ-B10/1FAZ-B10/2FAZ-B10/3FAZ-B10/4
    12FAZ-B12/1FAZ-B12/2FAZ-B12/3FAZ-B12/4
    13FAZ-B13/1FAZ-B13/2FAZ-B13/3FAZ-B13/4
    15FAZ-B15/1FAZ-B15/2FAZ-B15/3FAZ-B15/4
    16FAZ-B16/1FAZ-B16/2FAZ-B16/3FAZ-B16/4
    20FAZ-B20/1FAZ-B20/2FAZ-B20/3FAZ-B20/4
    25FAZ-B25/1FAZ-B25/2FAZ-B25/3FAZ-B25/4
    32FAZ-B32/1FAZ-B32/2FAZ-B32/3FAZ-B32/4
    40FAZ-B40/1FAZ-B40/2FAZ-B40/3FAZ-B40/4
    50FAZ-B50/1FAZ-B50/2FAZ-B50/3FAZ-B50/4
    63FAZ-B63/1FAZ-B63/2FAZ-B63/3FAZ-B63/4





    Trip Curve "C" Breakers

    Suitable for applications where medium levels of inrush
    current are expected. Instantaneous trip is 5 to 10 x rating
    of device (In). Applications include small transformers, lighting,
    pilot devices, control circuits and coils. Medium magnetic trip point.


    Rated
    Current
    In
    (A)
    1 pole2 poles3 poles4 poles
    TypeTypeTypeType
    0.5FAZ-C0.5/1FAZ-C0.5/2FAZ-C0.5/3FAZ-C0.5/4
    1FAZ-C1/1FAZ-C1/2FAZ-C1/3FAZ-C1/4
    1.6FAZ-C1.6/1FAZ-C1.6/2FAZ-C1.6/3FAZ-C1.6/4
    2FAZ-C2/1FAZ-C2/2FAZ-C2/3FAZ-C2/4
    3FAZ-C3/1FAZ-C3/2FAZ-C3/3FAZ-C3/4
    4FAZ-C4/1FAZ-C4/2FAZ-C4/3FAZ-C4/4
    6FAZ-C6/1FAZ-C6/2FAZ-C6/3FAZ-C6/4
    8FAZ-C8/1FAZ-C8/2FAZ-C8/3FAZ-C8/4
    10FAZ-C10/1FAZ-C10/2FAZ-C10/3FAZ-C10/4
    13FAZ-C13/1FAZ-C13/2FAZ-C13/3FAZ-C13/4
    16FAZ-C16/1FAZ-C16/2FAZ-C16/3FAZ-C16/4
    20FAZ-C20/1FAZ-C20/2FAZ-C20/3FAZ-C20/4
    25FAZ-C25/1FAZ-C25/2FAZ-C25/3FAZ-C25/4
    32FAZ-C32/1FAZ-C32/2FAZ-C32/3FAZ-C32/4
    40FAZ-C40/1FAZ-C40/2FAZ-C40/3FAZ-C40/4
    50FAZ-C50/1FAZ-C50/2FAZ-C50/3FAZ-C50/4
    63FAZ-C63/1FAZ-C63/2FAZ-C63/3FAZ-C63/4





    Trip Curve "D" Breakers

    Suitable for applications where high levels of inrush
    are expected. Instantaneous trip is 10 to 20 x rating
    of device (In). The high magnetic trip point prevents nuisance
    tripping in high inductive applications such as motors,
    transformers and power supplies.


    Rated
    Current
    In
    (A)
    1 pole2 poles3 poles4 poles
    TypeTypeTypeType
    6FAZ-D6/1FAZ-D6/2FAZ-D6/3FAZ-D6/4
    8FAZ-D8/1FAZ-D8/2FAZ-D8/3FAZ-D8/4
    10FAZ-D10/1FAZ-D10/2FAZ-D10/3FAZ-D10/4
    13FAZ-D13/1FAZ-D13/2FAZ-D13/3FAZ-D13/4
    16FAZ-D16/1FAZ-D16/2FAZ-D16/3FAZ-D16/4
    20FAZ-D20/1FAZ-D20/2FAZ-D20/3FAZ-D20/4
    25FAZ-D25/1FAZ-D25/2FAZ-D25/3FAZ-D25/4
    32FAZ-D32/1FAZ-D32/2FAZ-D32/3FAZ-D32/4
    40FAZ-D40/1FAZ-D40/2FAZ-D40/3FAZ-D40/4





    Copyright © 2008 -- Kent Industries Incorporated